Energy Management System & Power Grid Dispatching
سیستم مدیریت انرژی یکپارچه | کنترل فرکانس AGC/LFC | پایش گسترده WAMS/PMU | تحلیل امنیت N-1 | Economic Dispatch | State Estimation
رقیب Siemens Spectrum Power | ABB Network Manager | GE Grid Solutions
Real-time Grid Status | SCADA Integration | 1-Second Refresh
Interactive SLD | Click on breakers to toggle | Real-time values
Unit Commitment | Economic Dispatch | Merit Order | AGC Participation
| Rank | Unit | Capacity | Inc Cost | Current | Dispatch | AGC | Load % |
|---|---|---|---|---|---|---|---|
| 1 | Hydro #1 | 250 MW | 120 IRR | 180 | 180 | ✓ | |
| 2 | CCGT #2 | 500 MW | 920 IRR | 468 | 475 | ✓ | |
| 3 | CCGT #3 | 400 MW | 950 IRR | 385 | 390 | ✓ | |
| 4 | CCGT #1 | 450 MW | 980 IRR | 412 | 420 | ✓ | |
| 5 | Steam #1 | 320 MW | 1,250 IRR | 285 | 290 | ✓ | |
| 6 | Steam #2 | 280 MW | 1,450 IRR | 265 | 265 | - |
Automatic Generation Control | Load Frequency Control | Area Control Error
Wide Area Measurement System | Phasor Measurement Units | IEEE C37.118
N-1 Contingency Analysis | State Estimation | Optimal Power Flow
Under-Frequency Load Shedding | Under-Voltage Load Shedding | Black Start
Real-time Alarm Management | Event Log | Disturbance Recording
Weighted Least Squares | Bad Data Detection | Observability Analysis | Topology Processing
Security Constrained OPF | Loss Minimization | Congestion Management | Voltage Optimization
P-V Curves | Q-V Curves | Voltage Collapse Margin | Modal Analysis
Time Domain Simulation | Critical Clearing Time | Rotor Angle Stability | PSS Tuning
Bus-Branch Model | Switching Status | Island Detection | Connectivity Analysis
Dispatcher Training Simulator | Scenario Replay | Real-time Simulation | Operator Certification
50,000+ Points | 1-Second Scan | IEC 61850 / IEC 104 / DNP3
| Tag Name | Description | Value | Unit | Quality | Timestamp | Alarm |
|---|---|---|---|---|---|---|
| SYS.FREQ | System Frequency | 50.02 | Hz | Good | 14:32:15.123 | - |
| GEN.CCGT1.MW | CCGT #1 Active Power | 412.5 | MW | Good | 14:32:15.089 | - |
| GEN.CCGT1.MVAR | CCGT #1 Reactive Power | 85.2 | MVAr | Good | 14:32:15.089 | - |
| BUS.400.V | 400kV Bus Voltage | 402.3 | kV | Good | 14:32:15.045 | - |
| LINE.400-1.P | Line 400-1 Power Flow | 392.1 | MW | Good | 14:32:15.067 | ⚠ High |
| XFM.T1.TAP | Transformer T1 Tap | +3 | pos | Good | 14:32:14.892 | - |
| CB.400-G1.ST | Generator CB Status | CLOSED | - | Good | 14:32:15.012 | - |
| PMU.400-01.ANG | PMU Voltage Angle | 0.0 | deg | Good | 14:32:15.016 | - |
| AGC.ACE | Area Control Error | +2.5 | MW | Good | 14:32:15.001 | - |
| SUB.132-S.TEMP | Sub South Temp | 78.5 | °C | Suspect | 14:32:14.234 | 🔴 Crit |
IEC 61970/61968 | Common Information Model | Data Exchange
Enterprise Integration | GIS | OMS | DMS | Market | WAMS
Enterprise-grade Energy Management System | Comparable to Siemens Spectrum Power & ABB Network Manager
Equipment Naming & Identification | IEC 81346 Compatible
Enterprise Energy Management Platform | IEC 61850/61968/61970 Compliant